Evans has been meeting and exceeding the heating and air conditioning needs of Queenston, ON since 1967.
A hot water tank costs around $1,000-$3,000 in Queenston. Although, things that may cause the price to vary include:
- Whether you get a gas or electric water heater.
- The cost to remove the old water heater and install the new one.
- The contractor’s hourly rate.
To learn more about getting a hot water heater installed, contact us today.
An HVAC unit should be serviced twice a year in Queenston, once before cooling season and once before heating season. Having your HVAC system serviced before peak times allows you to prepare your HVAC system for these peak seasons. Additionally, having your HVAC unit serviced also enables you to spot repair needs before they become bigger issues in the long run. To find out more about getting your HVAC unit serviced, give us a call today.
To fix bad air quality in your Queenston home, you should:
- Clean and replace your air filters regularly.
- Regularly vacuum and clean your home.
- Open your windows to introduce fresh air into your home.
Monitoring your indoor air quality is important because poor indoor air quality can lead to worse allergies and health issues. The best way to maintain good air quality is to keep your home clean. Additionally, getting an air purifier is a great way to improve your indoor air quality. To get an air purifier for your home, call us today.
You may need to repair your HVAC unit in Queenston because:
- It is running, but not heating or cooling.
- It is not turning on.
- It cycles on and off too often.
It is important that you address issues with your HVAC system right away because some issues can end up damaging your entire system if left alone. A good way to prevent as many unexpected repairs in the future is to get your HVAC system on a maintenance plan so that it is regularly inspected and cleaned. Call us today to get your HVAC system repaired.
Read all about what your Queenston, ON neighbors are saying about our heating and air conditioning services in recent reviews below.
Recent Jobs and Reviews in Queenston, ON
Our Local Reviews by City
- Allanburg, ON (3)
- Beamsville, ON (1)
- Crystal Beach, ON (5)
- Dunnville, ON (1)
- Fort Erie, ON (59)
- Grimsby, ON (18)
- Hamilton, ON (1)
- Jordan Harbour, ON (1)
- Lincoln, ON (15)
- Niagara Falls, ON (1076)
- Niagara-on-the-Lake, ON (213)
- Pelham, ON (62)
- Port Colborne, ON (22)
- Queenston, ON (15)
- Ridgeville, ON (5)
- Ridgeway, ON (8)
- Smithville, ON (4)
- St. Catharines, ON (307)
- St. Davids, ON (1)
- Thorold, ON (70)
- Vineland, ON (1)
- Vineland Station, ON (4)
- Virgil, ON (40)
- Wainfleet, ON (2)
- Welland, ON (86)
- West Lincoln, ON (2)
Job Locations and Reviews
SLP99V, EL18XCV, Power Humidifier, S40
Furnace and air conditioning maintenance While inspecting the furnace, notice water at the bottom of the furnace and noticed a lot of water stains. Cut a hole in the supply plenum at the back of the furnace and noticed the air conditioning evaporator coil is leaking water onto the furnace. Back right hand side of the drain pan appears to have a small crack in it and the physical coil itself is rusting. Water leaking onto the furnace can cause damage to the furnace heat exchanger. The heat exchanger appears to have over heated at times and is turning purple / black. There are small stress cracks through out the heat exchanger. Heat exchanger is still in safe working order, but highly recommend getting a furnace inspection / maintenance yearly to ensure it’s still safe due to the condition it’s currently in. Due to the condition of the air conditioning evaporator coil, customer agreed to not do air conditioning maintenance, and would like to explore evaporator coil repalcement Vs
Air Conditioner installation
Service call for gas leak . Found one small leak on a joint above the furnace duct work of the gas line feeding the hot water tank . Removed about 7 feet of gas line ( 3 joints ) . Disassembled , cleaned , Teflon and re installed gas line . Tested with combustible gas leak detector all accessible gas line and soaped all fittings on water tank gas line no other leaks . Roughly 15 of 1 inch line in crawl space. Performed a dial tested on house and passed with no issues .
When repairing previous leak tried to leaks existing water shut off valve in instead of replacing. Unfortunately it developed a slow leak after the repair. Replaced water shut off with new ball valve and inspected for leaks, none found. Paid in full in cash - *please mail copy of receipt.*
Furnace Installation
Ac repair , furnace motor was not running , needed a new 5 mfd capacitor, condenser had also blown the 20 amp breaker , tested compressor motor and had a reading to ground of 34 k ohms but the unit is still running , tested after it ran for 10 mins and no reading to ground , I believe compressor is in the early stages of failure , customer would like to change the compressor because the house is for sale
Air Conditioner Installation service call. Performed full AC replacement, verified all components of the system were in good shape and operating correctly.
AC service call. Unit is out of refrigerant, leak in one of the coils. AC is a closed system with no option to hook up gauges. Recommended the install of a ductless AC as the best option.
Furnace and air conditioning maintenance. Furnace is In good shape for its age. Inspected heat exchanger. Has a lot of stress marks, and it’s very purple which is a sign of over heating. Venter motor is loud and could benefit replacing the motor. Air conditioning has very low charge of R22. Last years repot from our technician was 160 PISG on high, 60 PSIG on low. Today was 140 PSIG on the high 42 PSIG on the low. While doing a furnace maintenance, noticed the rental water heater exhaust flu collar popped off the venter motor. The exhaust pipe is too short and was forced into the flu collar during installation. Recommend to customer to call enercare to fix venting to prevent this from happening again.
Furnace Installation. Customer was looking for a new heater installation after their old unit stopped operating. Installed new unit, tested for proper operation, advised on important furnace maintenance to get the most out of it.
Heating repair service call. Secondary heat exchanger leaking. Will require replacement. Discussed furnace replacement due to age and condition of furnace.
Keeprite furnace maintenance, adjusted first stage gas pressures , fan speeds for blower motor were backwards on first stage and second stage , switched blue and red , vent drain diverter was plugged , removed blockage , inducer motor bearings starting to wear out and make noise on start up , humidistat was set to 10 % rh , adjusted to 40% also noticed old eac filter system , still works just inefficient
Daikin furnace maintenance, T stat down bottom not working anymore
Install air conditioner, air handler, and duct work.
Furnace and Ac maintenance and inspection
Diakins air conditioner maintenance
Installation of Navein Combi Boiler and Humidifier.
Install Lennox Furnace and Air Conditioner
Furnace and air conditioner maintenance.
Furnace and air conditioner maintenance.
Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.
Furnace repair. Cleaned drain line and trap.
Installed light bulbs in electric fireplace.
Furnace maintenance and inspection
Furnace maintenance.